PASSIVE WIRELESS INDUCTIVE CAPACITIVE LC SENSING TECHNIQUES FOR PROCESS PARAMETERSPERFORMANCE OF QUANTUM DOT BASED INTERMEDIATE BAND SOLAR CELLS

PASSIVE WIRELESS INDUCTIVE CAPACITIVE LC SENSING TECHNIQUES FOR PROCESS PARAMETERSPERFORMANCE OF QUANTUM DOT BASED INTERMEDIATE BAND SOLAR CELLS

Authors

  • Puja Acharya K.R. Mangalam University, Gurugram, Haryana, INDIA
  • Abhishek Chaudhary Sandip University (Sijoul)
  • Raju C K Sri Siddhartha Academy of Higher Education

Keywords:

Engineering, Passive Wireless, Capacitive Lc Sensing

Abstract

As a result of the rapid development that is taking place in a variety of commercial applications, such as the pharmaceutical industry, the processing of food and medication, nuclear power plants, and various biological applications, amongst other fields, there has been an increase in the demand for various new technologies. This demand has led to an increase in the availability of a variety of new technologies. The quick development that is taking place in these industrial applications is likely the cause of this demand. In order to facilitate the development of systems that are both safer and more effective, researchers are concentrating their efforts on the creation of surveillance techniques that are both accessible and inactive. These techniques will evaluate a variety of physical characteristics. These methods will evaluate the characteristics of the surroundings in which a system is operating. It is imperative that the characteristics of volume, pressure, flowrate, and emptiness percentage for two-phase flows be continuously monitored and evaluated. These characteristics are among the most crucial ones for a wide range of disciplines, and it is important to note that they play important roles. In addition, when working with processes that consist of two stages, these characteristics are required to be taken into consideration. The research that has been done in this area has presented a number of different methodologies that can be utilised in order to determine the aforementioned characteristics. These methodologies have the potential to be utilised in a variety of settings. The current body of research has led to the development of instruments that are capable of electronically measuring level, pressure, flowrate, and empty percentage independently of any active power source. These instruments have been created as a result of the research that is currently being conducted. The accumulation of this corpus of knowledge has made it feasible to produce these tools, which would not have been possible otherwise. The passive detection technology known as inductive-capacitive (LC) has been selected as the methodology of measurement that will be implemented for wireless applications. This technology will be used to determine signal strength. In the first piece of research, an LC sensing technology-based noncontact wireless inactive level sensor is introduced. This sensor does not require any physical contact. This instrument is a component of the surveillance device for the inactive level. This monitor is very mobile and does not have any attachments or connections that require it to make physical contact with anything.

References

Ali, S. F., & Mandal, N. (2021). Design and Development of Wireless Electronic Flow Transmitter Using Circular IDC as Primary Sensor. IEEE Transactions on Instrumentation and Measurement, 70. doi: 10.1109/TIM.2021.3075034

Asano, H., Takenaka, N., Fujii, T., Hayashi, H., & Wakabayashi, T. (2005). Visualization and void fraction measurement of gas-liquid two-phase flow in a commercial plate heat exchanger by thermal neutron radiography. IEEE Transactions on Nuclear Science, 52(1 II), 280–284. doi: 10.1109/TNS.2005.843676

Aschenbrenner, B., & Zagar, B. G. (2015). Analysis and validation of a planar highfrequency contactless absolute inductive position sensor. IEEE Transactions on Instrumentation and Measurement, 64(3), 768–775. doi: 10.1109/TIM.2014.2348631

Ayachit, A., & Kazimierczuk, M. K. (2017). Self-capacitance of single-layer inductors with separation between conductor turns. IEEE Transactions on Electromagnetic Compatibility, 59(5), 1642–1645. doi: 10.1109/TEMC.2017.2681578

Ayliffe, H. E., & Rabbitt, R. D. (2003). An electric impedance based microelectromechanical system flow sensor for ionic solutions. Measurement Science and Technology, 14(8), 1321–1327. doi: 10.1088/0957-0233/14/8/318

Babu, A., & George, B. (2016). A linear and high sensitive interfacing scheme for wireless passive LC sensors. IEEE Sensors Journal, 16(23), 8608–8616. doi: 10.1109/JSEN.2016.2614816

Babu, A., & George, B. (2018). An Efficient Readout Scheme for Simultaneous Measurement from Multiple Wireless Passive $lC$ Sensors. IEEE Transactions on Instrumentation and Measurement, 67(5), 1161–1168. doi: 10.1109/TIM.2017.2770858

Bao, K., Chen, D., Shi, Q., Liu, L., Chen, J., Li, J., & Wang, J. (2014). A readout circuit for wireless passive LC sensors and its application for gastrointestinal monitoring. Measurement Science and Technology, 25(8). doi: 10.1088/0957-0233/25/8/085104

Bekkeng. (2009). Model and Experimental Characterization of the Dynamic Behavior of Low-Power Carbon Monoxide MOX Sensors Operated With Pulsed Temperature Profiles. IEEE Transactions on Instrumentation and Measurement . 58(12),

Bera, S. C., Ray, J. K., & Chattopadhyay, S. (2004). A modified inductive pick-up type technique of measurement in a vortex flowmeter. Measurement, 35(1), 19–24. doi: 10.1016/J.MEASUREMENT.2003.08.019

Bera, Satish Chandra, & Chakraborty, B. (2009a). A novel technique of flow measurement for a conducting liquid. IEEE Transactions on Instrumentation and Measurement, 58(8), 2512–2517. doi: 10.1109/TIM.2009.2014620

Bera, Satish Chandra, & Chakraborty, B. (2009b). A novel technique of flow measurement for a conducting liquid. IEEE Transactions on Instrumentation and Measurement, 58(8), 2512–2517. doi: 10.1109/TIM.2009.2014620

Bera, Satish Chandra, & Mandal, H. (2012). A flow measurement technique using a noncontact capacitance-type orifice transducer for a conducting liquid. IEEE Transactions on Instrumentation and Measurement, 61(9), 2553–2559. doi: 10.1109/TIM.2012.2192345

Bera, Satish Chandra, Mandal, N., & Sarkar, R. (2011). Study of a pressure transmitter using an improved inductance bridge network and bourdon tube as transducer. IEEE Transactions on Instrumentation and Measurement, 60(4), 1453–1460. doi: 10.1109/TIM.2010.2090697

Bera, Satish Chandra, Sarkar, R., & Mandal, N. (2010). Study of the effect of excitation frequency on electrode polarization impedance-type flow transducer. IEEE Transactions on Instrumentation and Measurement, 59(12), 3289–3295. doi: 10.1109/TIM.2010.2047133

Kaushik P, Miglani S, Shandilya I, Singh A, Saini D,Singh A. HR Functions Productivity Boost by using AI. International Journal on Recent and Innovation Trends in Computing and Communication. 2023;11(8s):701-713. DOI: 10.17762/ijritcc.v11i8s.7672.

Published

2023-12-31

How to Cite

Acharya, P., Chaudhary, A., & C K, R. (2023). PASSIVE WIRELESS INDUCTIVE CAPACITIVE LC SENSING TECHNIQUES FOR PROCESS PARAMETERSPERFORMANCE OF QUANTUM DOT BASED INTERMEDIATE BAND SOLAR CELLS. IARS’ Knowledge Planet, (978-1-922642-02-8). Retrieved from https://jconsortium.com/index.php/iarsbookplanet/article/view/736
Loading...